Solar
Heat
»
HP Specifications
»
HP Collector
Returns
»
DF Specifications
»
DF Collector
Returns
|
Heat
Pipe Specifications
|
Type |
Unit |
HP-16 |
HP-12 |
HP-8 |
|
Number of tubes |
|
16 |
12 |
8 |
|
Collector surface (gross-base) |
m2 |
4,20 |
3,10 |
2,10 |
|
Aperture surface |
m2 |
3,00 |
2,25 |
1,50 |
|
Weight |
kg |
90 |
67 |
45 |
|
Dimensions |
L x B x D mm |
2140x1930x140 |
2140x1450x140 |
2140x970x140 |
|
Flow (m3/hour) |
min./opt./max. |
150/250/350 |
120/190/270 |
75/125/175 |
|
Pressure loss at 751/h |
mbar |
5 |
5 |
5 |
|
Liquid capacity |
1 |
2,30 |
1,80 |
1,15 |
|
Operating pressure |
bar |
6 |
6 |
6 |
|
max. stand still temp. collector |
°C |
180 |
180 |
180 |
|
Glass material |
high-quality boron silica glass |
|
Absorber material |
copper, selective layered |
|
High vacuum (long) |
bar |
10-8 |
10-8 |
10-8 |
|
Recommended placing angle |
|
25° to 70° |
25° to 70° |
25° to 70° |
|
Trial pressure |
bar |
10 |
10 |
10 |
|
Warranty |
Year |
5 |
5 |
5 |
|