Solar
Heat
»
HP Specifications
»
HP Collector
Returns
»
DF Specifications
»
DF Collector
Returns
|
Durch
Fluss Specifications
|
Type |
Unit |
DF-6 |
|
Number of tubes |
|
6 |
|
Collector surface (gross-base) |
m2 |
1,60 |
|
Aperture surface |
m2 |
1,10 |
|
Weight |
kg |
35 |
|
Dimensions |
L x B x D mm |
2160x720x120 |
|
Flow (m3/hour) |
L/H |
45/75 |
|
Pressure loss at 751/h |
mbar |
<30 |
|
Liquid capacity |
1 |
0,98 |
|
Operating pressure |
bar |
10 |
|
max. stand still temp. collector
max. stand
still temp. tubes |
°C
°C |
190
247
|
|
Glass material |
high-quality boron silica glass |
|
Absorber material |
copper, selective layered |
|
High vacuum (long) |
bar |
10-8 |
|
Recommended placing angle |
|
0° to 90°
(at one's discretion) |
|
Trial pressure |
bar |
12 |
|
Warranty |
year |
5 |
|